Reinforced Steel
- All rebar must be #40 grade and must be securely tied at both ends.
Footers
- One or two story - 16" x 8" with 2-#40 Grade Rebar
- Footers must be 12" below the frost line. The frost line is 24", thus all footers shall be at 36".
- Footings steel must be used as one of two grounds for the electrical panel.
Basement Foundation Walls
- 8" x 8'
- Horizontal - #4-40 Grade Rebar at each tie with 2-#4-40 Grade Rebar within the top 12"
- Vertical - #4-40 Grade Rebar at 24" on center both ways
Basement Floors
- Must have a minimum of 4" of crushed stone as a base
- Must have a minimum of 4" of concrete
- Must be reinforced with 6 x 6 x 10 wire mesh or #4-40 Grade Rebar at 24" on center both ways
Garage Floors
- Must have a minimum of 4" of crushed stone as a base
- Must have a minimum of 4" of concrete
- Must be reinforced with 6 x 6 x 10 wire mesh or #4-40 Grade Rebar at 24" on center both ways
- Must be pinned to the foundation with #4 Rebar
Driveways
- Must have a minimum of 4" of concrete
- Must be reinforced with 6 x 6 x 10 wire mesh or #4-40 Grade Rebar at 24" on center both ways
- Must be pinned to the foundation with #4 Rebar
Sidewalks
- Must have a minimum of 4" of concrete
- Must be reinforced rebar or wire mesh